A new biogenic sulfide chemical sensor for marine environmental monitoring and survey
OriginalPaper|Updated:2023-05-16
|
A new biogenic sulfide chemical sensor for marine environmental monitoring and survey
A new biogenic sulfide chemical sensor for marine environmental monitoring and survey
海洋湖沼学报(英文)2001年19卷第3期 页码:282-286
Affiliations:
Institute of Oceanology Chinese Academy of Sciences
Author bio:
Funds:
Contribution No. 3840 from the Institute of Oceanology, Chinese Academy of Sciences.;Project supported by the National Science Foundation for Outstanding Young Scientists (No. 49925614).
A new biogenic sulfide chemical sensor for marine environmental monitoring and survey[J]. 海洋湖沼学报(英文), 2001,19(3):282-286.
Jin-ming, S., Wei-dong, Z. A new biogenic sulfide chemical sensor for marine environmental monitoring and survey., Chin. J. Ocean. Limnol. 19, 282–286 (2001). https://doi.org/10.1007/BF02850666
A new biogenic sulfide chemical sensor for marine environmental monitoring and survey[J]. 海洋湖沼学报(英文), 2001,19(3):282-286. DOI: 10.1007/BF02850666.
Jin-ming, S., Wei-dong, Z. A new biogenic sulfide chemical sensor for marine environmental monitoring and survey., Chin. J. Ocean. Limnol. 19, 282–286 (2001). https://doi.org/10.1007/BF02850666DOI:
A new biogenic sulfide chemical sensor for marine environmental monitoring and survey
摘要
Abstract
A new convenient sulfide electrochemical sensor for marine environmental in-situ monitoring and real time survey was developed. The new sensor based on a solid Ag2S membrane electrode has outstanding chemical sensitivity and stability. It responds to the activity of sulfide ions according to a Nernstian slope of −31mV/decade. The sensor can be used to determine the total concentration of sulfides (C T) by calibrating the pH value of the solution to a standard pH. The practical measurement range for total sulfide concentration is 0.1–10 mg/L in seawater. The sensor has a very low potential drift (<4 mV) during two months in 0.1 mg/L sulfide seawater. This paper describes the preparation of the sensitive membrane and some main properties of the sensor.
关键词
Keywords
references
Luther III, G. W., Tsamakis, E., 1989. Concentration and Form of Dissolved Sulfide in the Oxic Water Column of the Ocean.Mar. Chem. 27 (3–4): 165–177.
Mor, E., Scotto, V., Marcenaro, G. et al., 1975. The Use of Membrane Electrodes in the Determination of Sulfide in Seawater.Anal. Chim. Acta. 75: 159–167.
Mascini, M., Liberti, A., 1970. Preparation and Some Analytical Applications of a New Sulfide-Selective Heterogeneous Membrane Electrode.Anal. Chem. Acta. 51: 231–237.
Pungor, E., Schmidt, E., 1971. Studies on Sulfide Selective Membrane Electrodes.Anal. Lett. 4: 641–653.
Song Jinming, Li Pengcheng, 1996. −2 Valence Sulfur of Lagoon and Off-Reef Sediment Interstitial Waters of Nansha Islands, South China Sea.Oceanol. Limnol. Sin. 27(6): 590–597. (in Chinese with English abstract)
Song Jinming, 1997. Chemistry of Sediment-seawater Interface of the China Seas. China Ocean Press, Beijing, p. 1–222.
Vesely, J., Jensen, O. J., NicoLaisen, B., 1972. Ion-Selective Electrodes Based on Silver Sulfide.Anal. Chim. Acta. 62: 1–13.
Visscher, P. T., Beukema, J., 1991. In-situ Characterization of Sediments Measurement of Oxygen and Sulfide Profiles with Novel Combined Needle Electrode.Limnol. Oceanogr. 36 (7): 1476–1480.